Vulnerability Assessment Scanning and Penetration Testing by VSS, LLC.
Home


Search:


APC Smart-UPS RT-3000, SURTD3000XLT, AP9631 Net Managment Card, New Batteries For Sale


APC Smart-UPS RT-3000, SURTD3000XLT, AP9631 Net Managment Card, New Batteries

This item has been shown 2 times.

Buy Now

APC Smart-UPS RT-3000, SURTD3000XLT, AP9631 Net Managment Card, New Batteries:
$400

This is a APC Smart-UPS RT-3000, SURTD3000XLT, AP9631 Net Managment Card, New Batteries

What you will get:

  • APC Smart-UPS RT-3000, SURTD3000XLT UPS
  • UPS Network Management Card 2 with Environmental Monitoring AP9631
  • New Batteries installed in the 2 cartridiges
  • Manual Network Management Card Keyed SmartSlot Upgrade and Installation
  • Safety Guide Smart UPS SU and SURT Under 5000 VA Uniterruptable Power Supply
  • Product Registration Card
  • Installation and Operation Smart-UPS RT SURTD3000/5000XL Tower Rack Mount Uniterruptable Power Supply
  • CD Smart-UPS RT UserManual
  • CD Power-Chute Business Edition Version 8.5
  • Cable

Description:

This is a APC Smart-UPS RT-3000, SURTD3000XLT, AP9631 Net Managment Card, New Batteries. I did change the batteries in the 2 "cartridges" andtested the unit. This is my item 9699. Please see my other itemswhere I have 3 more of these units without the UPS Network Management Card 2 with Environmental Monitoring AP9631 and the batteries in the "cartridges" are dead.

This is HEAVY. I welcome local pickup in Natick, MA.

Please use the shipping calculator to determine shipping.

More Information:

Marketing Features:

  • Avoids costly power problems by keeping your IT equipment and data protected and available. Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
  • Low operating and maintenance costs with proven reliability and intelligent battery management. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
  • Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
  • Save time with easy and convenient remote accessibility. Network manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Protection
  • Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse.
  • Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Cold-start capable Provides temporary battery power when the utility power is out.
Serviceability
  • Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Predicitive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
  • Disconnected battery notification Warns when a battery is not available to provide backup power.
  • Audible alarms Provides notification of changing utility power and UPS power conditions
  • User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Adaptability
  • Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
  • Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
  • Flash upgradeable firmware Install maintenance releases of firmware remotely using FTP.
Manageability
  • SmartSlot Customize UPS capabilities with management cards.
  • InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager.
  • LED status indicators Quickly understand unit and power status with visual indicators.
  • Network manageable Provides remote power management of the UPS over the network.
  • Serial connectivity Provides management of the UPS via a serial port.
Availability
  • Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
  • Scalable runtime Allows additional run time to be quickly added as needed.
  • Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.
  • Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.

Documentation and Links:

  • Manual for the APC Smart-UPS On Line SURT 3/5/6 kVA 200-240 Vac TWR/RM3U
  • Link to the APC Web Site where this is described
  • UPS Network Management Card 2 - Installation Guide
  • UPS Network Management Card 2 - User Guide v6.4.6
  • UPS Network Management Card 2 - CLI (Command Line Interface) help, v6.4
  • UPS Network Management Cards : Installing Multiple Management Cards (Manual Addendum)
  • UPS Network Management Card 2 - Release Notes, v6.4.6
  • Network Management Card 2 Release Notes, V. 6.4
  • UPS Network Management Card 2 - User Guide, v6.4

Please use the shipping calculator to determine shipping.

See my other itemswhere I have other weight sets / scales / scientific equipment, shakers, stirrers,

If you receive your item and it is not to your 100 Percent Satisfaction, please contact us before leaving response. I strive to make sure every transaction is a positive one!

I wanted to reach out and let you know that is changing the way Sellers are rated. I am not overjoyed with what's happening, but I have to roll with it. IF you have a problem with my item, I would like you to use the "Contact Seller" link in the listing, or call me. Please don't open a case. Cases count against me even if they are resolved. I stand behind my items and will work out any problems that you may have with an item. So please contact me if you have a problem with an item I have sold you and don't use the Case as a means of communication.

International Buyers, Please Note:

Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.

Please check with your country's customs office to determine what these additional costs will be prior to offerding/buying.

These charges are normally collected by the delivering freight (shipping) company or when you pick the item updo not confuse them for additional shipping charges.

We do not mark merchandise values below value or mark items as "gifts".

US and International government regulations prohibit such behavior.


Buy Now

Other Related Items:



Cyberpower Pr3000swrm2u Battery Set picture
Cyberpower Pr3000swrm2u Battery Set


Liebert Powersure Ps3000rt2-120 Battery Set picture
Liebert Powersure Ps3000rt2-120 Battery Set


Liebert Powersure Ps1440rt2-120 Battery Set picture
Liebert Powersure Ps1440rt2-120 Battery Set


Cyberpower Ur700rm1u Battery Set picture
Cyberpower Ur700rm1u Battery Set


Cyberpower Pp1500swt2 Battery Set picture
Cyberpower Pp1500swt2 Battery Set


Apc Be750g Back-ups Es 750va/450w 120v 10-outlet Ups Surge Protector New Battery picture
Apc Be750g Back-ups Es 750va/450w 120v 10-outlet Ups Surge Protector New Battery


Apc Be750g Back-ups Es 750va 450w 10-outlet Ups Surge Protector New Battery picture
Apc Be750g Back-ups Es 750va 450w 10-outlet Ups Surge Protector New Battery


Power Backup Supply Uninterrupted Power Mini Battery For Camera 12v2a 22.2w Ups  picture
Power Backup Supply Uninterrupted Power Mini Battery For Camera 12v2a 22.2w Ups


8-outlet Ups Battery Backup Computer Uninterruptible Power Supply Surge Protect picture
8-outlet Ups Battery Backup Computer Uninterruptible Power Supply Surge Protect


Powerware 9125 Online Ups Pw9125 1250 Uninterruptible Power Supply 1250va 875w picture
Powerware 9125 Online Ups Pw9125 1250 Uninterruptible Power Supply 1250va 875w



VSS, LLC.

P.O. Box 827051

Pembroke Pines, FL 33082-7051

Vulnerability Scanning Solutions, LLC.